Eaton
SVX006A1-4A1B1B5B9C2
Adjustable Variable Speed / Frequency Drive (AFD/VSD/VFD) / Inverter with 3RO (NO) + 1RO (NO) + 5DI (42-240V) + Modbus communication option cards - Eaton / Cutler-Hammer (SVX) - Rated input voltage (3-phase (3P)) 380Vac-500Vac - Rated output current 12A (Low overload IL) - Rated power 5.5kW (Low overload IL) / 7.5HP (Low overload IL) - Frame size FR4 - UL type 1 / NEMA 1 - with EMC filter (class H) - with Modbus communication capability - with Brake chopper
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
SVX006A1-4A1B1B5B9C2
Net Price
$5,561.78
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Eaton - SVXSVX006A1-4A1B1B5B9C2
Description
Adjustable Variable Speed / Frequency Drive (AFD/VSD/VFD) / Inverter with 3RO (NO) + 1RO (NO) + 5DI (42-240V) + Modbus communication option cards - Eaton / Cutler-Hammer (SVX) - Rated input voltage (3-phase (3P)) 380Vac-500Vac - Rated output current 12A (Low overload IL) - Rated power 5.5kW (Low overload IL) / 7.5HP (Low overload IL) - Frame size FR4 - UL type 1 / NEMA 1 - with EMC filter (class H) - with Modbus communication capability - with Brake chopper
Specifications
Primary brand
Eaton
Secondary brand
Cutler-Hammer
Main function
Variable Speed / Frequency Drive (VSD/VFD) / Inverter
Product series / family name
SVX
Network frequency
(input) 45-66 Hz
(output) 0-320 Hz
(output) 0-320 Hz
Functions
Adjustable Variable Speed / Frequency Drive (AFD/VSD/VFD) / Inverter with 3RO (NO) + 1RO (NO) + 5DI (42-240V) + Modbus communication option cards
Brake chopper
Brake chopper
Supply voltage (AC)
380Vac-500Vac
Type of network
3-phase input (3P)
Rated current
12A (Low overload IL)
9A (High overload IH)
9A (High overload IH)
Rated active power (kW)
5.5kW (Low overload IL)
Rated power (HP)
7.5HP (Low overload IL)
Protection functions
Overcurrent
Overvoltage
Undervoltage
Earth fault
Input phase supervision
Motor phase supervision
Overtemperature
Motor overload
Motor stall
Motor underload
Short-circuit
Overvoltage
Undervoltage
Earth fault
Input phase supervision
Motor phase supervision
Overtemperature
Motor overload
Motor stall
Motor underload
Short-circuit
Communication protocol
Modbus
Operating mode
Frequency control (V/f)
Open loop; Sensorless vector control
Open loop; Sensorless vector control
Digital inputs
6 x digital inputs (programmable)
Digital outputs
2 x digital outputs (SPDT Single Pole Double Throw contact type)
1 x digital output (Open collector)
1 x digital output (Open collector)
Analog inputs
2 x analog inputs (0-20mA / 4-20mA / 0-10V DC)
Analog outputs
1 x analog output (0-20mA)
Degree of protection
UL type 1
NEMA 1
NEMA 1
Ambient air temperature for operation
-10...+40 °C
Ambient air temperature for storage
-40...+70 °C
Technology used in component
EMC filter (class H)
Manufacturer product status
Commercialized
Compliant with standard(s)
IEC 61800-2
EN 61800-3
UL 508C
CE
EN 61800-3
UL 508C
CE
Benefits
Robust design proven 500000 hours MTBF
Integrated 3% line reactors standard on drives from FR4 through FR9
Simplified operating menu allows for typical programming changes
Quick Start Wizard built into the programming of the drive ensures a smooth start-up
Keypad can display up to three monitored parameters simultaneously
LOCAL/REMOTE operation from keypad
Copy/paste function allows transfer of parameter settings from one drive to the next
Flexibly adapted to a variety of needs using our pre installed “Seven in One” precision application programs
Additional I/O and communication cards provide plug and play functionality
I/O connections with simple quick connection terminals
Hand-held auxiliary 24 V power supply allows programming/monitoring of control module without applying full power to the drive
Control logic can be powered from an external auxiliary control panel; internal drive functions and fieldbus if necessary
Standard option board configuration includes an A9 I/O board and an A2 relay output board installed in slots A and B
Integrated 3% line reactors standard on drives from FR4 through FR9
Simplified operating menu allows for typical programming changes
Quick Start Wizard built into the programming of the drive ensures a smooth start-up
Keypad can display up to three monitored parameters simultaneously
LOCAL/REMOTE operation from keypad
Copy/paste function allows transfer of parameter settings from one drive to the next
Flexibly adapted to a variety of needs using our pre installed “Seven in One” precision application programs
Additional I/O and communication cards provide plug and play functionality
I/O connections with simple quick connection terminals
Hand-held auxiliary 24 V power supply allows programming/monitoring of control module without applying full power to the drive
Control logic can be powered from an external auxiliary control panel; internal drive functions and fieldbus if necessary
Standard option board configuration includes an A9 I/O board and an A2 relay output board installed in slots A and B
Related Documents
Name | Last Update | Language |
---|---|---|
Eaton - PowerXL M-Max SVX H-Max SPX EGF CFX HCX CPX RGX LCX SPA SPN SPI - Catalogue.pdf | 23 Jun 2020 | English (US) |